TAC Nortel/Bix Connector 25 Pair

SAR20.00
In stock
SKU
E-CO-FNOR25

The connector's symmetrical construction allows termination of cables on one side and cross-connect jumper wires or BIX patch cords on the other. Each BIX connector is equipped with 50 double-ended Insulation Displacement Connection (IDC) clips for terminating plastic insulated solid copper conductors without stripping. The connector is built with two staggered rows of IDC clips enclosed in a three-layer construction of fire-retardant plastic wafers. Pair splitters on each side of the connector facilitate wire insertion.

Technical Specification

Materials:

Housing material:  Fire-retardant thermoplastic

IDC clips: Phosphorus bronze with tin plating over nickel.

Mechanical Characteristics:

Connection: 22, 24 & 26 AWG plastic insulated solid copper conductors.

Durability: 200 Insertions.

Electrical Characteristics:

Dielectric Strength:  1000 Volts RMS at 60 Hertz for 1 Minute.

Current Rating:  1.5 Amperes maximum.

Insulation Resistance:  100 mega ohm minimum between clips.

Contact Resistance:  1 mille-ohm per contact.