TAC CAT3 Indoor Telecom Cables
Description
TAC Category 3 cables are used for voice, data communication and interconnection of telephone key system, PBX and intercom systems.
For Roll length please check below in details.
|
Conductor AVG Insulation Thickness (mm) MIN Insulation Thickness (mm) Insulation Material (mm) Insulation Dia. (mm) AVG Jacket Thickness (mm) MIN Jacket Thickness (mm) Outer Dia. (mm) Jacket Material Rip cord |
solid bare copper 0.20 0.18 HDPE 0.90±0.02 0.50 0.40 3.0x4.5 PVC No |
Physical Specification
|
Electrical and Transmission CHARACTERISTICS |
|||||||
|
Frequency |
MHz |
0.772 |
1 |
4 |
8 |
10 |
16 |
|
Attenuation @ 20°C |
db/100m |
2.2 |
2.6 |
5.6 |
8.5 |
9.7 |
13.1 |
|
Next @ 20°C |
db/100m |
43 |
41 |
32 |
28 |
26 |
23 |
|
SRL @ 20°C |
db/100m |
12 |
12 |
12 |
12 |
12 |
10 |
|
Characteristic Impedance (Ohms): 100+/-15 |
|||||||
|
Delay Skew (ns/100m): 45 |
|||||||
|
DC Resistance (Ohms/100m): 9.38 |
|||||||
|
Ordering Code |
Pair Count |
Conductor Dia. |
Length |
Jacket Color |
||
|
AWG |
mm |
mtr. |
Ft. |
|||
|
E-WI-T2-24 |
2 |
24 |
0.5 |
150 |
500 |
Grey |
|
E-WI-T3-24 |
3 |
24 |
0.5 |
150 |
500 |
Grey |
|
E-WI-T4-24 |
4 |
24 |
0.5 |
150 |
500 |
Grey |
|
E-WI-T6-24 |
6 |
24 |
0.5 |
150 |
500 |
Grey |
|
E-WI-T10-24 |
10 |
24 |
0.5 |
305 |
1000 |
Grey |
|
E-WI-T12-24 |
12 |
24 |
0.5 |
305 |
1000 |
Grey |
|
E-WI-T25-24 |
25 |
24 |
0.5 |
305 |
1000 |
Grey |
|
E-WI-T50-24 |
50 |
24 |
0.5 |
305 |
1000 |
Grey |
|
E-WI-T100-24 |
100 |
24 |
0.5 |
305 |
1000 |
Grey |
|
E-WI-T25-22 |
25 |
22 |
0.6 |
305 |
1000 |
Grey |
|
E-WI-T50-22 |
50 |
22 |
0.6 |
305 |
1000 |
Grey |
|
E-WI-T100-22 |
100 |
22 |
0.6 |
305 |
1000 |
Grey |